INSTALLATION
QUICK-START
A typical system will use an IR receiver, several emitters, and a power supply
all connected to a connecting block.
MODEL
48095D
1. Connect the IR receiver to the “IR RCVR” port on the connecting
block. The ‘red’ connector is installed to the ‘red’ plug.
Note: In some extended distances, additional 3-conductor may be required and can
be connected to the terminals on the connecting block.
Dinky Link™ Surface Mount
Plasma Proof IR Receiver
2. Connect the Emitters to the connecting block. The ‘yellow’ connector
is installed to the ‘yellow’ plug.
3. Connect the power supply to the connecting block.
4. Installation complete
INSTALLATION INSTRUCTIONS
DESCRIPTION
REMOTE ROOM APPLICATION
These small IR receivers have been designed for mounting in very small
spaces. They may be mounted under shelf edges, cabinet ledges, in wall
speakers, etc. – anywhere an inconspicuous appearance is desired. The
high sensitivity of these receivers allows placement behind speaker grilles
and still receive IR commands up to 20 feet away.
One application is to locate the IR receiver in a remote room. This will give
the end-user the ability to control audio/video equipment from a location
where the remote control no longer has the ability of direct line-of-sight.
The IR receiver will need the 3.5mm stereo type mini plug removed to extend
the wire run to the connecting block. A 3-terminal block is supplied to connect
the IR receiver to the connecting block with a 3-conductor inter-room cable in
between.
FEATURES
•
•
•
•
Very small package, only 2.45”L x 0.45”W x 0.35”H.
Wire channel for clean installation.
System testing red-talk-back LED.
The 3-conductor inter-room cable (24 gauge up to 200’, 22 gauge up to 600’,
20 gauge up to 2000’, 18 gauge up to 5000’), is run to the main room.
Includes 3-Terminal Block for easy extension to remote room locations.
SPECIFICATIONS
•
•
•
•
•
•
•
•
•
Infrared carrier frequency bandwidth: 30 - 100kHz.
Reception range: Up to 30 feet, depending on conditions.
Nominal reception angle: 55 degrees off axis.
Cable requirements: See “INSTALLATION” below.
Max. transmission length: 1 mile using 18 gauge wire.
Maximum current output: 100mA
Drives IR emitters through Xantech Connecting Blocks, Controllers, etc.
Dimensions: 2.45”x0.45”x0.35” (63mm x 12mm x 9mm)
Power requirements: +12VDC, 20mA.
3.5mm mini plug
TIP
RING
Signal Name
SIGNAL
GROUND
+12VDC
While it is possible to make wired connections without the connecting block,
it is not recommended. The connecting block reduces installation time, helps
to eliminate errors, allows easy troubleshooting and permits easy system
upgrades later, if needed.
SLEEVE
|