Wybron Power Supply PS 150 User Manual

Power Supplies  
User Manual  
 
3
 
Safety Information  
SAVE THESE INSTRUCTIONS  
READ AND FOLLOW ALL INSTRUCTIONS  
This manual gives step-by-step instructions for the preparation, setup, and operation of  
the PS-150, PS-300 and PS-600 Power Supply.  
There is a potential risk of fire, electric shock or injury to persons if the product is not  
used as instructed.  
WARNING: When using electrical appliances, use basic precautions, including:  
Read this manual before connecting power.  
Use supervision around children.  
Use in a dry location only.  
The PS Power Supply is to be used in an indoor environment only and is not intended  
for residential use.  
For continued protection against risk of fire, replace only with same type and rating of  
fuse.  
Protection against electric shock is assured only if the mains connected power supply  
cord set is connected to a properly earthed grounding type receptacle.  
An all pole disconnect device must be located adjacent to the unit or, if the AC cord is  
used as the main disconnect device, ensure that the socket-outlet is located/installed  
near the equipment and is easily accessible.  
THE MAINS LEADS ARE COLORED IN ACCORDANCE WITH THE FOLLOWING  
CODE AND MUST BE CONNECTED IN THE FOLLOWING SCHEME:  
-
-
-
GREEN AND YELLOW: EARTH  
BLUE: NEUTRAL  
BROWN: LINE  
WARNING: THIS EQUIPMENT MUST BE EARTHED.  
Product Modification Warning  
Wybron, Inc. products are designed and manufactured to meet the requirements of  
United States and International safety standards. Modifications to the products could  
affect safety and render the product non-compliant to relevant safety standards.  
4
 
Notes de Sécurité  
EPARGNER CES INSTRUCTIONS  
LIRE ET SUIVRE TOUTES INSTRUCTIONS  
Ce manuel donne des instructions pour la preparation, l’organisation, et l’opération du le  
PS provision d'électricité.  
Il y a un risqué de feu, décharge électrique, ou la blessure aux gens si le produit n’est  
pas utilize comme instruit.  
AVERTISSEMENT: En utilisant des appareils électriques utilise la prudence  
fondamentale inclut:  
Lire ce manuel avant d'alimenter ou l'installation de l'accessoire.  
Utiliser la prudence près des enfants.  
Sécher l'emplacement seulement.  
Le PS provision d'électricité va être utilize à la maison seulement et pas pour l’usage  
residential.  
Pour la protection continuée contre le risque de feu, remplacer seulement avec le  
même type et le même classement de fusible.  
La Protection contre la décharge électrique est seulement assurée si la série de corde  
connectée principale est connectée à un convenablement terre de type.  
Un appareil débranchant doit être localisé à côté de l'unité ou, si la corde de courant  
alternatif est utilisée comme le principal débranche l'appareil, S'assurer que la douille-  
sortie localise/installé près de l'équipement et est facilement accessible.  
LES AVANCES PRINCIPAUX SONT CONFORMEMENT COLORES AU CODE  
SUIVANT ET DOIVENT ETRE CONNECTES DANS L'ARRANGEMENT SUIVANT :  
vert et jaune– terre  
bleu – neutre  
marron – ligne  
L'AVERTISSEMENT – CET EQUIPEMENT DOIT ETRE FONDE.  
L’Avertissement de Modification de Produit  
Les produits de Wybron, Inc. sont conçus et a fabriqué pour rencontrer les conditions  
d’Etats-Unis et de norms de sûreté internationals. Les modifications aux produits  
pourraient affecter la sûreté et rendent le produit non-conciliant aux normes de sûreté  
pertinentes.  
5
 
Aviso Sobre Seguridad  
SALVE ESTAS INSTRUCCIONES  
LEA Y SIGA TODAS INSTRUCCIONES  
Este manual da el paso por paso las instrucciones para la preparación, para arreglo, y  
para la operación de la PS fuente del poder.  
Hay un riesgo potencial del fuego, el calambre o la herida a personas si el producto no  
se utiliza como instruido.  
ADVERTENCIA: Cuando se usa electrodomésticos, el uso las precauciones básicas,  
incluyendo:  
Lea este manual antes de accionar o instalar la instalación fija.  
Supervise a niños cercano.  
Seque ubicación sólo.  
La PS fuente del poder deberá ser utilizado en un ambiente interior sólo y no es  
pensado para el uso residencial.  
Para la protección continuada contra el riesgo del fuego, reemplaza sólo con mismo  
tipo y calificación de fusible.  
La Protección contra calambre se asegura sólo si el conjunto conectado principal de  
cuerda es conectado a un apropiadamente earthed que muele receptáculo de tipo.  
Una toda asta desconecta dispositivo se debe localizar adyacente a la unidad o, si la  
cuerda de C.A. se utiliza como el principal desconecta dispositivo, asegure que la  
enchufe-salida localiza/instalado cerca del equipo y sea fácilmente accesible  
EL PRINCIPAL DIRIGE SON COLORADOS DE ACUERDO CON EL CODIGO  
SIGUIENTE Y se DEBE CONECTAR EN EL ESQUEMA SIGUIENTE:  
verde y amarillo – molió/la tierra  
azul – neutral  
brown – línea  
La ADVERTENCIA – ESTE EQUIPO DEBE SER EARTHED.  
Advertencia de Modificación de Producto  
Wybron, los productos S.a. se diseñan y son fabricados para encontrar los requisitos de  
Estados Unidos y estándares Internacionales de seguridad. Las modificaciones a los  
productos podrían afectar la seguridad y rendir el producto no conformista a estándares  
pertinentes de seguridad.  
6
 
Sicherheitshinweise  
BEHALTEN SIE DIESEN ANWEISUNGEN  
LESEN SIE UND GEHORCHEN SIE ALLEN ANWEISUNGEN  
Dieses Handbuch gibt Schritt für Schritt Anweisungen zur Vorbereitung, Aufstellung,  
und Funktion dem PS Quelle der Kraft.  
Es gibt ein potenzielles Risiko des Feuers, Elektroschocks oder Verletzung zu  
Personen, wenn das Produkt nicht benutzt ist, als unterrichtet ist.  
WARNUNG: Beim Benutzen elektrischer Geräte, Gebrauch grundlegende  
Vorsichtsmaßnahmen, einschließlich:  
Lesen Sie dieses Handbuch vor Betreiben oder Installieren des Inventar.  
Benutzen Sie Aufsicht nahe Kinder.  
Trocken Sie Ort nur.  
Der PS Quelle der Kraft soll in einer Hallenumwelt nur benutzt werden und ist für  
Heimumwelt nicht vorgehabt.  
Für fortgesetzten Schutz gegen Risiko des Feuers, ersetzt nur mit gleichem Typ und  
Bewertung der Sicherung.  
Schutz gegen Elektroschock ist nur gezusichert, wenn die Hauptleitungen Schnursatz  
verbunden haben, ist an eine ordentlich earthed Erdung von Behälter angeschlossen.  
Eine alle Stange schaltet Vorrichtung muss sich befunden werden neben der Einheit ab  
oder, Wenn die AC Schnur benutzt ist, während die Hauptleitung Vorrichtung  
abschaltet, Sichert, dass der Steckdosensteckdose ist befunden/nahe die Ausrüstungen  
installieren, und ist leicht zugänglich.  
DIE HAUPTLEITUNGEN BLEIE SIND GEMÄSS DEM FOLGENDEN CODE GEFÄRBT  
UND MÜSSEN IM FOLGENDEN SCHEMA VERBUNDEN WERDEN:  
Grün und Gelb – Erden Sie/Erde  
Blau – neutral  
Braun – linie  
WARNUNG – DIESE AUSRÜSTUNGEN MUSS EARTHED WERDEN.  
Produktänderungswarnung  
Wybron, Inc. Produkte sind entworfen und sind hergestellt, die Voraussetzungen von  
Vereinigten Staaten und Internationalen Sicherheitsstandards zu erfüllen. Änderungen  
zu den Produkten könnten Sicherheit beeinflussen und könnten das Produkt leisten das  
verordnungswidrig ist zu relevanten Sicherheitsstandards.  
7
 
Introduction  
The PS-150, PS-300 and PS-600 are Wybron’s new RDM compatible Power Supplies.  
The power supplies work with their compatible devices, allowing you to control the fan  
speed (where applicable) via one or multiple DMX channels on the lighting console.  
Plus, the compact power supplies attach easily to the truss of the lighting rig or mount  
into a 19-inch rack.  
System Components  
Power Supply  
The power supply passes the DMX512 signal level from the lighting console and then  
sends to each device along with 24 volts DC. The DMX512 control signal from the  
lighting board is connected to the power supply and can continue on to more power  
supplies or other DMX-controlled devices. The power supply sends both power and  
control signal on a single cable eliminating the need for a separate power cable for each  
device attached.  
Caution: The PS Power Supply is currently only compatible with  
Forerunner and NexeraLX. DO NOT connect PS Power Supplies to  
RAM/ColoramII devices (ColoramII, CXI, GoboramII, or Eclipse) and DO  
NOT connect Forerunner or NexeraLX to RAM/Coloram II Power Supplies.  
Damage from such action will not be covered by the equipment warranties.  
Compatible Devices  
At the time of printing of this manual, the PS-150, PS-300 and PS-600 Power Supplies  
are only for use with the following devices:  
Nexera LX  
Forerunner color changers  
Refer to the Nexera LX or Forerunner user manuals for detailed operating information  
on these products. More products will be compatible in the future.  
To operate Forerunner: The maximum amount of cable per power supply output is 350  
feet. The maximum number of color changers per power supply output is eight (8).  
Power/Data Cable  
The Power/Data Cable connects the Power Supply outputs to the connected devices  
and provides them with power and control signal. The cable uses 4-pin XLR connectors  
on either end and consists of two 14 AWG conductors and a 22 AWG twisted, shielded  
pair.  
8
 
Example of a system layout:  
PS Power Supply  
NexeraLX  
Forerunner  
AC Power  
DMX control  
console  
DMX512  
Equipment Compatibility  
The following is a chart of compatibility and capacity of the various models of PS Power  
Supplies and the companion devices. This is current as of the print date of this manual.  
As more products are added to the compatible line, an updated list will be available on  
Power Supply:  
Model Number:  
Output Power:  
PS-150  
20150  
150 watts  
PS -300  
20300  
300 watts  
PS -600  
20600  
600 watts  
Quantity per Power Supply:  
Max.  
Head-Feet  
Description  
Model  
PS-150  
PS-300  
PS-600  
2560,2570,  
2640  
2580,2600,  
2650  
NexeraLX - tungsten  
NexeraLX - CDM  
1500  
1500  
8
6
16  
12  
32  
24  
Forerunner – 4 inch  
Forerunner – 7 inch  
4540  
7140  
n/a  
n/a  
16  
16  
32  
32  
64  
64  
The above information assumes devices are on different channels and all move simultaneously  
9
 
Installing / Connecting the Power Supply  
To get your Power Supply up and running, follow these hookup and checkout  
procedures.  
1.  
Mount the power supply  
The Power Supply is designed to be free standing, truss mounted, or rack  
mounted.  
The power supply comes with a mounting bracket which hooks over the pipe or  
truss of your lighting rig and is then locked into place with a thumb screw. If you  
have selected this mounting method, connect the power supply's safety cable by  
clipping it around the pipe or truss.  
The power supply can also be mounted into a 19" rack using the optional rack  
mount kit. The rack mount kit will accommodate two power supplies side by side.  
2.  
3.  
Connect the device to the power supply  
Connect the device to the power supply using a 4-pin Wybron Power/Data cable.  
Refer to the HEAD-FEET RESTRICTION section of the manual for details of the  
length of cable runs.  
Note: The Wybron Power/Data Cable has been specially designed to minimize  
voltage drop -- use only Wybron supplied cable.  
Connect the Power Supply to AC power  
Plug the AC cord into a non-dimmed power circuit. The power supply  
automatically accommodates 100 – 240V ~ 50/60 Hz.  
Caution: Do not power the power supply from a dimmed circuit.  
Severe damage will result and is not covered by product warranty.  
Power at the power supply is indicated by the red LED which can be viewed from  
the stage.  
10  
 
4.  
Connect and set the DMX512 source  
Connect the DMX512 signal source to the DMX input connector on the front of  
the power supply using standard DMX cable. The DMX signal will be indicated by  
a flashing green LED. The DMX signal will now position the gelstrings/vanes  
according to their respective DMX signal levels.  
Head-Feet Restrictions  
The HEAD-FEET parameter is a method of accounting for the voltage drop in the  
power/signal cable caused by the current drawn by each device.  
To help understand this issue, think of it as water pressure (voltage) in a hose (cable)  
where you have multiple water sprinkler heads (color changers). If the hose (cable) is  
too long or you have too many sprinkler heads (color changers), the water pressure  
(voltage) will be too low.  
HEAD-FEET is defined as "the sum of cable lengths from each device to a single power  
supply output".  
Refer to the user manual of the specific components for detailed head-feet information  
on those products.  
Mounting and Installation Accessories  
The following sections describe the procedures for installation and replacement of  
mounting accessories.  
Power Supply hanger brackets  
The power supplies are shipped with hanger brackets to allow pipe or truss mounting.  
Follow these steps to install the hanger bracket.  
1. Disconnect AC power from the power supply.  
2. Place the power supply on its side on a flat surface.  
3. Position the brackets as shown on the next page.  
4. Attach the bracket using a 3/16" Allen wrench and the supplied screws.  
11  
 
Note: Use the supplied thumb screws to clamp the hanger brackets to the desired pipe  
or truss.  
B
O
AT  
L
B
O
AT  
L
6
0
2
3
11  
/
0
5
V
A
-
V
A
-
25  
2
0
V
C
-
4
A
AM  
AM  
P
P
SL  
90  
SL  
Power Supply Hanger Brackets  
Power supply rack mounting  
The rack mount accessory can be used with up to two power supplies and allows them  
to be mounted into a 19-inch rack.  
Follow these steps to install the power supply into the rack mounting tray.  
1. Disconnect AC power from the power supply.  
2. Place the rack mount tray right side up on a flat surface.  
3. Position the power supply in the rack mount tray as shown below.  
4. Attach the power supply to the rack mount tray using the supplied screws.  
Note: The cover plate may be removed to allow installation of a second power supply.  
screws  
Rack Mount Tray  
12  
 
Cables  
Power/Data Cable  
The Power/Data Cable uses 4-pin XLR connectors on either end and consists of two 14  
AWG conductors and a 22 AWG twisted, shielded pair. The shells of the two XLR  
connectors are not electrically connected together -- this prevents large power currents  
from flowing from chassis to chassis of the equipment. The twisted pair shield is  
connected at male XLR connector end only.  
XLR Pin # Wire Color Function  
Size  
1
2
3
4
White  
Green  
Red  
Ground  
Data -  
Data +  
24VDC  
14 AWG  
22 AWG  
22 AWG  
14 AWG  
Black  
DMX512 Control Cable  
The DMX control cable from the lighting console to the power supply is a five conductor  
cable with 5-pin XLR connectors on each end. The wiring pin out is specified by the  
USITT DMX512/1990 standard.  
XLR Pin # Function  
1
2
3
4
5
Common  
Data -  
Data +  
Talkback -  
Talkback +  
13  
 
Specifications  
PS-150, PS-300 and PS-600 Power Supply  
Connectors:  
DMX in: Male 5-pin XLR  
DMX out: Female 5-pin XLR  
Output: Female 4-pin XLR  
DMX512 termination: None – DMX signal pass thru  
Fuse:  
PS-150 (model 20150):  
Input voltage: 100-240V ~ 50/60 Hz 3-1.5A  
250V 2A Slo Blo for 100-120V~  
250V 1A Slo Blo for 220-240V~  
PS-300 (model 20300):  
Input voltage: 100-240V ~ 50/60 Hz 5-3A  
250V 4A Slo Blo for 100-120V~  
250V 2A Slo Blo for 220-240V~  
PS-600 (model 20600):  
Input voltage: 100-240V ~ 50/60 Hz 10-5A  
250V 7A Slo Blo for 100-120V~  
250V 4A Slo Blo for 220-240V~  
Input Power: Automatically accepts 100-240V ~ 50/60 Hz  
Input Signal: 1990 USITT standard DMX512  
Red LED: Indicates power  
Green LED: Indicates DMX signal  
Size:  
PS-150:  
12.7"/323mm L x 7.6"/193mm W x 2.9"/74mm H  
Weight: 3.9 lbs/1.8 kg  
PS-300:  
14"/356mm L x 7.8"/198mm W x 3"/76mm H  
Weight: 5.4 lbs/2.4 kg  
PS-600:  
14”/356mm L x 7.8”/198mm W x 4.1”/104mm H  
Weight: 7.9 lbs/3.6 kg  
14  
 
Parts List  
To order any of the following items, contact your authorized WYBRON dealer.  
The PS Power Supplies  
20150.......................................................... PS-150  
20300.......................................................... PS-300  
20600.......................................................... PS-600  
The PS Mounting and Installation Accessories  
715-01-03P ................................................. PS-150, PS-300 and PS-600 hanger bracket  
SCRWC252075........................................... Wing screw for power supply hanger  
bracket to pipe  
SCRSC2520037.......................................... Socket cap screw for hanger bracket to  
power supply  
Power/Data Cable  
7042-3......................................................... 3' power/signal cable  
7042-5......................................................... 5' power/signal cable  
7042-10....................................................... 10' power/signal cable  
7042-15....................................................... 15' power/signal cable  
7042-25....................................................... 25' power/signal cable  
7042-50....................................................... 50' power/signal cable  
7042-75....................................................... 75' power/signal cable  
7042-100..................................................... 100' power/signal cable  
15  
 
Warranty Information  
WYBRON, INC. warrants to the original owner or retail customer that for a period of one  
year from date of delivery of a portable system or energization of a permanently  
installed system (up to a maximum of 18 months from delivery) its products will be free  
from defects in materials and workmanship under normal use and service.  
Warranty does not cover any product or part of a product subject to accident,  
negligence, alteration, abuse, misuse or any accessories or parts not supplied by  
WYBRON, INC. Warranty does not cover "consumable" parts such as fuses, lamps, or  
color media. WYBRON, INC.'s warranty does not extend to items not manufactured by  
us. Freight terms on warranty repairs are FOB WYBRON, INC. factory or designated  
repair facility. Collect shipments or freight allowances will not be accepted.  
WYBRON, INC.'s sole responsibility under this warranty shall be to repair or replace at  
WYBRON, INC.'s option such parts as shall be determined to be defected on  
WYBRON, INC.'s inspection. WYBRON, INC. will not assume any responsibility for any  
labor expended or materials used to repair any equipment without WYBRON, INC.'s  
prior written authorization. WYBRON, INC. shall not be responsible for any incidental,  
general or consequential damages to property, damages for loss of use, time, profits or  
income, or any other charges.  
The owner's obligations during the warranty period under this warranty are to notify  
WYBRON, INC. at WYBRON, INC.'s address within one week of any suspected defect,  
and return the goods prepaid to WYBRON, INC. at their factory or authorized service  
center.  
This warranty is contingent on the customer's full and timely compliance with the terms  
of payment set forth in said purchase order. This warranty is expressly in lieu of any and  
all other warranties expressed or implied including the warranties of merchantability and  
fitness for a particular purpose and of other obligations and liabilities on our part. The  
owner acknowledges that no other representations were made to him or relied upon him  
with respect to the quality and function of the goods sold.  
This written warranty is intended as a complete and exclusive statement of the terms  
thereof. Prior dealings or trade usage shall not be relevant to modify, explain or vary this  
warranty. Acceptance of, or acquiescing in, a course of performance under this warranty  
shall not modify the meaning of this agreement even though either party has knowledge  
of the performance and a chance to object.  
WYBRON, INC. - FAX 719-548-0432  
- TEL 719-548-9774  
Email: [email protected] - Visit us on the World Wide Web at http://www.wybron.com  
16  
 

Wells Oven B406 User Manual
West Bend Kitchen Grill Sandwich Maker User Manual
Whirlpool Ventilation Hood GZ7930XHS0 User Manual
Whirlpool Washer Dryer LCE4332PQ0 User Manual
Williams Gas Heater 0556541 User Manual
Wolf Cooktop SRT304 User Manual
Wolfgang Puck Cookware Center Fill Bakeware Set User Manual
Xantrex Technology Battery Charger Freedom 458 User Manual
Xilinx Automobile Automotive User Manual
Zenoah Gas Grill EDG2300 User Manual